MIL-PRF-85725A(AS)
TABLE V. Group C inspection.
Inspection
Requirement
Method
paragraph
Paragraph
4.5.2.1
High temperature
3.4.1.1
4.5.2.2
Low temperature
3.4.1.2
4.5.2.3
Temperature shock
3.4.1.3
4.5.2.4
Humidity
3.4.1.4
4.5.2.5
Fungus
3.4.1.5
Salt fog
3.4.1.6
4.5.2.6
Acceleration
3.4.1.7
4.5.2.7
Vibration
3.4.1.8
4.5.2.8
Shock
3.4.1.9
4.5.2.9
Crash safety
3.4.1.10
4.5.2.10
Guide rails
3.4.2.1
4.5.3.1
Tier insertion/extraction
1/
3.4.2.2
4.5.3.2
Pressure drop
3.4.2.3
4.5.3.3
Leakage
3.4.2.4
4.5.3.4
Thermal
3.4.3
4.5.4
Shielding outside-to-inside
3.4.4.1.1
4.5.5.1.1
Shielding tier-to-tier
3.4.4.1.2
4.5.5.1.2
1/ This test is not applicable for Format E designs.
4.4 Inspection conditions. The following conditions shall be used to establish normal
performance characteristics under standard conditions and for making laboratory bench tests.
a. Temperature: room ambient (25 °C ± 10 °C (77 °F ± 18 °F )).
b. Altitude: normal ground.
c. Humidity: room ambient up to 90 percent relative humidity.
4.5 Inspection methods.
4.5.1 Examination. The racks shall be examined to determine compliance with the
requirements of 3.2, 3.3, 3.5, 3.7, and 3.8.
4.5.1.1 Weight. There shall be no visual distortion when the maximum weight per tier is
applied to the rack (see 3.6).
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.