MIL-DTL-24705B(SH)
3.5.12 Infrared (IR) signature. The IR signature of the insert material shall be determined as specified in
4.6.14. At the time of qualification, this signature shall be marked for identification by the Government inspector
and shall be retained by the manufacturer as standard for the purpose of determining conformance (see 4.4.1.1.2).
3.6.1 Frames and accessories. Unless otherwise specified (see 6.2), frames and accessories shall be
permanently marked by ink, stamping, molding, casting, or be engraved with the following:
a.
Military part number (see 3.1).
b.
Manufacturer's name or logo.
Identification marking shall be at a location that will be clearly visible once the multiple cable penetrator has been
assembled. Printed characters shall be approximately 3 mm high or larger, and shall be clear, complete, and legible
to the naked eye.
3.6.1.1 Accessories. Accessories consist of end-packing assembly, compression plate, and stay plate.
3.6.2 Cable insert blocks. Cable insert blocks shall be permanently marked by molding, engraving, or indelible
stamping with the following:
a.
Exterior width and passage diameter in mm (see 3.1).
b.
Passage diameter in inches (see 3.1).
c.
Manufacturer's name or logo.
Unless otherwise specified (see 3.1), passage diameter shall be marked in mm and inches on each end face of the
cable insert block. The individual specification sheets shall specify the marking required for small block sizes or for
blocks with large passage diameters that restrict marking space availability. Location of other required
identification marking shall be at the option of the manufacturer. Printed characters shall be complete and legible to
the naked eye.
3.7 Workmanship. Workmanship shall he in accordance with MIL-HDBK-454.
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as follows:
a.
Prequalification inspection (see 4.2).
b.
Qualification inspection (see 4.3).
c.
Conformance inspection (see 4.4).
d.
Material control objective quality evidence (see 4.5).
4.1.1 Inspection conditions. Unless otherwise specified herein, all measurements shall be made within the
following ambient conditions:
a.
Temperature: 15 to 35 degrees Celsius (°C).
b.
Atmospheric pressure: 550 to 800 mm of mercury (Hg).
c.
Relative humidity (RH): 20 to 80 percent.